Back to the list of connectors
Dell iDRAC - Storage
Description
This connector provides server storage monitoring through Dell's iDRAC Management Card for Dell servers with iDRAC7 or later.
Connector ID: DelliDRACStorage
This connector is superseded by:
Target
Typical platform: Dell PowerEdge
Operating system: Out-of-Band
Prerequisites
Leverages: Dell iDRAC Management Card (iDRAC7 or Later)
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t management -f DelliDRACStorage --snmp v2c --community publichws-config.yaml
hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ DelliDRACStorage ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secureConnector Activation Criteria
The Dell iDRAC - Storage connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4must return a value in the same subtree
Metrics
| Type | Collected Metrics | Specific Attributes (Labels) | 
|---|---|---|
| Enclosure | 
 | 
 | 
| Disk Controller | 
 | 
 | 
| Battery | 
 | 
 | 
| Fan | 
 | 
 | 
| Logical Disk, RAID | 
 | 
 | 
| Other Device | 
 | 
 | 
| Physical Disk | 
 | 
 | 
| Power Supply | 
 | 
 | 
Search Results for {{siteSearch | truncate:'50'}}
							{{resultArray.length}}
							
						
						
						
						
						
					
						No results.