Back to the list of connectors
EMC VPLEX Version 6
Description
It monitors the Enclosure and Physical Disks as well as the various environment sensors (fans, power supplies, Memory, Directors and Network cards)
Connector ID: VPLEX
This connector supersedes:
Target
Typical platform: EMC VPLEX
Operating system: Storage System
Prerequisites
Leverages: EMC VPLEX REST API Version 6 and Higher
Technology and protocols: HTTP/REST
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
hws HOSTNAME -t storage -f VPLEX --https --http-port 443 -u USERNAMEhws-config.yaml
hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ VPLEX ] # Optional, to load only this connector
  http:
    https: true
    port: 443 # or probably something else
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt
Connector Activation Criteria
The EMC VPLEX Version 6 connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The HTTP Request below to the managed host succeeds: 
    - GET /vplex/engines
 
- GET 
Metrics
| Type | Collected Metrics | Specific Attributes (Labels) | 
|---|---|---|
| Enclosure | 
 | 
 | 
| Fan | 
 |  | 
| Memory Module | 
 | 
 | 
| Network Card, FC Port | 
 | 
 | 
| Other Device | 
 | 
 | 
| Physical Disk | 
 | 
 | 
| Power Supply | 
 | 
 | 