35 Changes - Released 2021-06-17What's New
| ID | Description |
|---|---|
| SWSY-4351 | Extensive support for Prometheus: Export to Prometheus and consume from Exporters |
| SWSY-4225 | Database Query: Added support for IBM Informix |
| SWSY-4326 | Database Query: Added support for Oracle Database Server versions 12.1, 12.2, 18.3, 19.x and 20.x |
| SWSY-4340 | Web UI and REST API overall performance improvement |
| SWSY-4349 | Dates and times can be extracted and interpreted in Numeric Value Extractions |
| SWSY-4424 | Added support for Java 16 |
| SWSY-4433 | Complete overhaul of WMI-based collection for improved scalability (no VBScript) |
Changes and Improvements
| ID | Description |
|---|---|
| SWSY-3929 | Web UI: KM developers can customize how Monitoring Studio displays custom KMs (icons, buttons, etc.) |
| SWSY-4361 | Numeric Value Extraction is able to interpret scientific notation (e.g. 6.02e+23) |
| SWSY-4429 | Numeric Values Extraction can automatically find the position of the numeric value to be extracted, anywhere in the line |
| SWSY-4139 | Improved download of large files from the PATROL Agent through TSPS |
| SWSY-4214 | Performance has been improved when downloading a Template as a .CFG |
| SWSY-4256 | Web UI: 30-second execution timeout has been removed from PSL Playground |
| SWSY-4310 | Special characters may be escaped in macro content, e.g. %{USERNAME_ESC_JSON} |
| SWSY-4322 | SNMP Polling: Context Name and Context Engine ID can be customized in SNMP Credentials (SNMP v3) |
| SWSY-4419 | Database Query: Support for multiline SQL queries and scripts (bonus: SQL syntax highlighting) |
| SWSY-4430 | Content-parsing Monitors: Multiple columns can be extracted |
| SWSY-4244 | Database Query: Added support for SCRAM-SHA-256 authentication in PostgreSQL |
| SWSY-4436 | Dry Run is disabled for children Monitors that have not been collected successfully |
Fixed Issues
| ID | Description |
|---|---|
| SWSY-4223 | TLS v1.3 causes high CPU usage with Java 11 and higher |
| SWSY-4243 | Dynamic instances of String Searches, Numeric Value Extractions and Value Maps keep being collected while paused by the user |
| SWSY-4356 | Web UI: Console shows Internal Error 500 when querying instances with '#' in their path |
| SWSY-4262 | Remote File Monitoring: Files with wildcards trigger an alert on Collection Error parameter instead of Present parameter when file is absent |
| SWSY-4360 | TSPS Plugin: Online help of other KMs cannot be accessed in the Console page |
| SWSY-4371 | Alert Actions: Macro variables related to the alert are not translated in the Alert Action Monitor |
| SWSY-4378 | Nagios Plugin may trigger a false timeout alert if multiple collects happen simultaneously |
| SWSY-4379 | Local Command Lines may trigger a false timeout alert if multiple collects happen simultaneously |
| SWSY-4381 | Command Line Monitor: Execution time out is inaccurately reported |
| SWSY-4388 | SNMP Trap Monitor: Unable to detect SNMP traps when the trap number is not specified |
| SWSY-4405 | Windows Performance Counter: Value is not collected when object instance name contains a backslash |
| SWSY-4413 | Event Management KM thresholds applied on Dynamic Instances are overridden with Template's thresholds |
| SWSY-4428 | Missing Dynamic Instances are deleted one collect late |
| SWSY-4458 | String Search: the Acknowledge String may not be taken into account if an acknowledge timeout is set |
| SWSY-4465 | String Search: The Acknowledge String In Column Number(s) cannot be saved in the Web interface |
| SWSY-3922 | Folder monitoring: Wrong value of some parameters when the folder or the filename contains a semicolon |
Monitoring Studio KM for PATROL 10.2.00
31 Changes - Released 2020-12-23What's New
| ID | Description |
|---|---|
| SWSY-4110 | Web UI: New interface to manage and customize Agent Alert Thresholds for all KMs |
Changes and Improvements
| ID | Description |
|---|---|
| SWSY-3616 | Web UI: Possibility to test the SMTP settings in the Monitoring Studio Settings |
| SWSY-3966 | Web UI: Possibility to customize collectionErrorCountAutoAcknowledgeTime |
| SWSY-4215 | Web UI: Performance when loading the Console page has been improved to display thousands of objects |
| SWSY-4242 | Alert Message Macros: PATROL Agent namespace variables can be inserted through the new %{/...} macro |
| SWSY-4266 | TSPS Component: Event's objects slot is missing in TrueSight Event page |
| SWSY-4277 | Dynamic Instances that go missing (Present = 0) can be manually removed in the Console UI |
| SWSY-4278 | Web UI: Multiple IP addresses are properly displayed in the Agent Information page |
| SWSY-4283 | X_TEMPLATE class: CollectionErrorCount is now refreshed every 10 minutes |
| SWSY-4306 | Integration to Helix Operations Management can now be fine-tuned from the Web interface |
| SWSY-4314 | Installing the TSPS Component in a clustered environment is now documented |
| SWSY-4318 | Web UI: API Key for Helix Operations Management can be modified in Agent Settings |
| SWSY-4321 | Web UI: Console refreshes data, status and values automatically |
| SWSY-4324 | Web UI: Performance when loading the Studio page has been improved |
| SWSY-4330 | PATROL REST API: Add the possibility to sort operations by tag |
| SWSY-4217 | Alert Message Macros: %{USERNAME} can be used by instances attached to Monitors with configured credentials |
Fixed Issues
| ID | Description |
|---|---|
| SWSY-4317 | Security: Code injection vulnerability in TSPS Component allows remote authenticated users to run arbitrary PSL code on PATROL Agents via HTTP headers and request body |
| SWSY-4222 | Bad Request message is returned when accessing Monitors containing backslashes in their IDs |
| SWSY-4246 | HTTP Request: %{TIME} macro was not interpreted in the body of HTTP Request Monitors |
| SWSY-4255 | Customized cookie name in RSSO prevents users from accessing TSPS when Monitoring Studio X Component is loaded |
| SWSY-4258 | Macro %{USERNAME} is not interpreted |
| SWSY-4263 | Web UI: Dry Run not working when the host is configured through CMA and associated with multiple Templates |
| SWSY-4282 | Web UI: When connecting to TSPS with Monitoring Studio, the URL redirects to an internal RSSO |
| SWSY-4291 | Web UI: Unable to log in as a non-default account on Linux and UNIX systems |
| SWSY-4300 | HTTP Server: Memory leak when handling REST API calls |
| SWSY-4302 | Alerts are not triggered at the expected time when the occurrence is set to N times in a row |
| SWSY-4308 | TrueSight Component: Unable to access Monitoring Studio X interface through TSPS when the KM is not loaded on the agent |
| SWSY-4316 | Studio: Default alert thresholds defined in class may remain active even when disabled in the Template |
| SWSY-4319 | PATROL REST API: POST/PUT requests in Swagger UI are rejected by TSPS |
| SWSY-4327 | Instances attached to PSL Command or Nagios Plugin Monitors may be incorrectly created in the OFFLINE state (paused) when the PATROL Agent starts |
| SWSY-4173 | Web UI: Special characters (like '#') in the Config Hacker are not supported |
Monitoring Studio KM for PATROL 10.1.02
10 Changes - Released 2020-03-26Changes and Improvements
| ID | Description |
|---|---|
| SWSY-4134 | Polling of SNMP tables now supports ranges for column numbers |
| SWSY-4221 | Web UI: Previous LOG files of the PATROL Agent (*.errs.~1~, etc.) can be downloaded from the Agent Information page |
| SWSY-4224 | Numeric Value Extraction: Values suffixed with '%', 'KiB', 'MiB' or 'GiB' are supported |
| SWSY-4234 | Web UI: System uptime is displayed in the Agent Information page |
Fixed Issues
| ID | Description |
|---|---|
| SWSY-4219 | Accessing the Web UI through TrueSight when the KM is not loaded causes 100% processor time usage by the PATROL Agent |
| SWSY-4226 | Web UI: The interface fails to load in the browser when the version of the PATROL Agent is 20.x |
| SWSY-4228 | Web UI: In some cases, the links in the grey bar under the Studio tab don't scroll to the corresponding section |
| SWSY-4231 | Numeric Value Extraction: Delta per Minute and Delta per Hour values are incorrect |
| SWSY-4232 | Dynamic Objects are not created on a Text Pre-Processing object during the first discovery upon agent startup |
| SWSY-4229 | Web UI: Studio page shows incorrect System Type when Monitored Hosts are configured through a policy in TrueSight |
Monitoring Studio KM for PATROL 10.1.01
7 Changes - Released 2020-01-30Changes and Improvements
| ID | Description |
|---|---|
| SWSY-4198 | Monitoring Studio discovery and overall responsiveness have been greatly optimized |
| SWSY-4213 | Web UI: The Studio page loads faster, even with large number of defined Monitors |
Fixed Issues
| ID | Description |
|---|---|
| SWSY-4203 | TSPS stops working after configuration of Monitoring Studio X Component |
| SWSY-4062 | Monitoring Studio allows Host SNMP checks even if SNMP is disabled |
| SWSY-4132 | Pause monitoring automatically resumes after 1 hour |
| SWSY-4206 | In TrueSight CMA, deployment of the KM is reported as failed on Linux and UNIX systems, KM is not preloaded |
| SWSY-4212 | Web UI: The Console fails to load details for instances with Text parameters containing special characters |
Monitoring Studio KM for PATROL 10.1.00
23 Changes - Released 2019-12-17What's New
| ID | Description |
|---|---|
| SWSY-4111 | Monitoring Studio X User Interface Can Be Accessed Through TrueSight Presentation Server |
| SWSY-4112 | Interactive System Shell and PSL Playground |
Changes and Improvements
| ID | Description |
|---|---|
| SWSY-3625 | Add the possibility to change the certificate of the HTTPS server |
| SWSY-4071 | File System: New parameter "Present" to monitor the presence of the file system |
| SWSY-4073 | Web UI: Time scale of graphs must show 1:00, 1:05, 1:10, etc. rather than 0.59, 1:04, 1:09, etc. |
| SWSY-4074 | Database Query: Connection to Oracle Database is now made with Service Name instead of Database Name |
| SWSY-4078 | SSH: Support for SHA2 algorithms for HMAC and Kex |
| SWSY-4128 | Database Query: Support for MySQL Server version 8 |
| SWSY-4178 | Expose the version of Monitoring Studio to PSL and Web UI |
| SWSY-4183 | Parameters of the main "Monitoring Studio X" instance are collected every 10 minutes instead of 10 seconds |
Fixed Issues
| ID | Description |
|---|---|
| SWSY-4080 | The value of macros containing PASSWORD in their label is not encrypted |
| SWSY-4070 | Web UI: Searching in the online documentation does not produce any result |
| SWSY-4097 | Name of an Embedded File in a Template could not be modified once an invalid characters was entered |
| SWSY-4106 | String Search: The %{LAST_MATCHING_LINES} parameter does not properly report on the actual last matching lines |
| SWSY-4108 | String Search: Non-applicable Acknowledging Options are visible when String Search reports "Matches in Current Collect Only" |
| SWSY-4118 | Web UI: In rare occasions, the Events Auto-Refresh thread would remain active even after the user leaves the view |
| SWSY-4127 | KM-level Configuration Mode (CMA or Classic) is overriden by Agent-level Configuration Mode |
| SWSY-4154 | %{PASSWORD} macros are not translated in HTTP Requests, Database Queries and PSL Scripts |
| SWSY-4155 | HTTP Request: HTTP request body is malformed when configured as a JSON form |
| SWSY-4158 | Folder: Parameter NewFileRate is not collected |
| SWSY-4169 | Command Line: Multibyte charsets are not supported through SSH and result gets truncated |
| SWSY-4176 | When running in a Container, the HTTP server delivers an authentication token that does not apply to correct port number |
| SWSY-4182 | Web UI: Modal when importing an existing Template gets truncated (top is hidden by main nav bar) |