Back to storage intelligence reference

HPE Primera (WBEM)

Storage Intelligence file name: HPE-Primera-WBEM.si

Description

This storage intelligence adapter discovers storage systems and collects performance/capacity metrics for HPE Primera platforms.

Target

Typical platforms: Primera, 3PAR

Prerequisites

Relies on: HPE Primera Web Services API (WSAPI)

Technology and protocol: WBEM

Default Port Number: 5989

Notes

This storage intelligence adapter is not compatible with HPE Primera software versions 4.5.3 and 4.5.4 due to the HPE Primera issue 370176, C28803.

Monitors

Object Type Infobox Parameters
Controller (SKM_CONTROLLER)
  • Memory Size
  • Number Of Ports
  • PATROL ID
  • Serial Number
  • Bandwidth Utilization
  • Cache Hit Ratio
  • Operation Rate
  • Present
  • Processor Utilization
  • Read Byte Rate
  • Read Operation Percentage
  • Read Operation Rate
  • Read Response Time
  • Response Time
  • Status
  • Status Information
  • Transfer Byte Rate
  • Write Byte Rate
  • Write Operation Percentage
  • Write Operation Rate
  • Write Response Time
Physical Disk (SKM_PHYSICALDISK)
  • Firmware Version
  • Manufacturer
  • Model
  • PATROL ID
  • Serial Number
  • Size
  • Speed
  • Type
  • Operation Rate
  • Present
  • Read Byte Rate
  • Read Operation Rate
  • Read Response Time
  • Response Time
  • Status
  • Status Information
  • Transfer Byte Rate
  • Write Byte Rate
  • Write Operation Rate
  • Write Response Time
Port (SKM_PORT)
  • Address
  • Maximum Port Speed
  • PATROL ID
  • Role
  • Type
  • Bandwidth Utilization
  • Link Speed
  • Link Status
  • Present
  • Read Byte Rate
  • Read Response Time
  • Response Time
  • Status
  • Status Information
  • Transfer Byte Rate
  • Write Byte Rate
  • Write Response Time
Storage Pool (SKM_STORAGEPOOL)
  • Capacity
  • PATROL ID
  • Size
  • Configured Capacity
  • Consumed Capacity
  • Consumed Capacity Percentage
  • Operation Rate
  • Oversubscription Situation
  • Read Byte Rate
  • Read Operation Rate
  • Status
  • Subscribed Capacity
  • Subscribed Capacity Percentage
  • Transfer Byte Rate
  • Write Byte Rate
  • Write Operation Rate
Storage System (SKM_SYSTEM)
  • Capacity
  • Family
  • Hostname
  • Meta Entity Type
  • Model
  • Number of Disks
  • PATROL ID
  • Serial Number
  • Size
  • Vendor
  • Available Capacity
  • Bandwidth Utilization
  • Configured Capacity
  • Consumed Capacity
  • Count
  • License Count
  • Operation Rate
  • Oversubscription Situation
  • Read Byte Rate
  • Read Operation Rate
  • Read Response Time
  • Response Time
  • Spare Disk Count
  • Status
  • Subscribed Capacity
  • Transfer Byte Rate
  • Write Byte Rate
  • Write Operation Rate
  • Write Response Time
Storage Volume (SKM_VOLUME)
  • Mapped
  • NAA
  • PATROL ID
  • RAID Level
  • Volume Type
  • Volume Usage
  • Consumed Capacity
  • Consumed Capacity Percentage
  • Host Visible Capacity
  • Hosts
  • Operation Rate
  • Queue Length
  • Read Byte Rate
  • Read Operation Rate
  • Read Response Time
  • Response Time
  • Status
  • Status Information
  • Time Since Last Activity
  • Transfer Byte Rate
  • Write Byte Rate
  • Write Operation Rate
  • Write Response Time
No results.