Back to the list of connectors

IBM DS (LSI) Disk Arrays (smcli)

Description

This connector enables hardware monitoring for IBM DS storage systems through the SMCli utility.

Connector file name: MS_HW_smcli.hdf

This connector is superseded by:

Target

Typical platforms: IBM DS3000, IBM DS4000, IBM DS5000

Operating system: Storage System

Prerequisites

Leverages: The SMcli utility, which is part of IBM DS Storage Manager. The version must be compatible with the system being monitored. Multiple versions of SMcli on the same system is not supported.

Technology and protocols: System Commands

This connector requires advanced privileges on the managed host for the command below:

  • Second_Address

This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo on the managed host to allow the monitoring account to run the command listed above.

Sample of /etc/sudoers to allow the above command to be run as root by the patrol account:

patrol ALL=(root) NOPASSWD: Second_Address

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The IBM DS (LSI) Disk Arrays (smcli) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • Operating System is Storage System
  • The command below succeeds on the agent host
    • Command: SMcli
    • Output contains: Incorrect (regex)
  • The command below succeeds on the agent host
    • Command: SMcli %{HOSTNAME} -c "show StorageSubsystem;"
    • Output contains: drive (regex)

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Additional Information 1
  • Serial Number
  • Type
  • Vendor
Battery (MS_HW_BATTERY)
  • Status
  • Additional Information 1
Blade (MS_HW_BLADE)
  • Status
  • Additional Information 1
  • Blade Model
  • Serial Number
Fan (MS_HW_FAN)
  • Status
  • Additional Information 1
Logical Disk, RAID (MS_HW_LOGICALDISK)
  • Status
  • Additional Information 1
  • Size
Network Card, FC Port (MS_HW_NETWORK)
  • Link Speed
  • Link Status
  • Additional Information 1
  • Physical Address
  • Physical Address Type
Other Device (MS_HW_OTHERDEVICE)
  • Status
  • Additional Information 1
  • Device Type
Physical Disk (MS_HW_PHYSICALDISK)
  • Status
  • Additional Information 1
  • Model
  • Serial Number
  • Size
  • Vendor
Power Supply (MS_HW_POWERSUPPLY)
  • Status
  • Additional Information 1
Temperature Sensor (MS_HW_TEMPERATURE)
  • Status
  • Additional Information 1
No results.