-
Home
- Storage Analyzer KM
Release Notes
This page lists the new features, improvements, changes and bug fixes in each version of Storage Analyzer.
Storage KM 1.9.00
1 Changes - Released 2024-08-28Changes and Improvements
ID | Description |
---|---|
SKM-324 | Storage Intelligence updated to version 31 |
Storage Intelligence 31
3 Changes - Released 2024-08-14What's New
ID | Description |
---|---|
SI-379 | Added support for IBM Spectrum Protect (REST) |
SI-378 | Added support for Dell EMC Avamar (REST) |
Fixed Issues
ID | Description |
---|---|
SI-383 | Hitachi E Series, G Series (REST): The "Enable Hardware Monitoring" option is not available |
Storage Intelligence 30
3 Changes - Released 2024-07-19What's New
ID | Description |
---|---|
SI-319 | Added support for Dell EMC VPLEX (REST) |
Changes and Improvements
ID | Description |
---|---|
SI-374 | HPE Primera (WBEM): The calculation of the Processor Utilization parameter has been improved |
Fixed Issues
ID | Description |
---|---|
SI-375 | Ceph (REST): API calls may fail and trigger an HTTP Error 415 - Unsupported Media Type |
Storage Intelligence 29
3 Changes - Released 2024-06-17What's New
ID | Description |
---|---|
SI-330 | Added support for IBM Spectrum Control (REST) |
Fixed Issues
ID | Description |
---|---|
SI-372 | IBM DS8000 (REST): An unexpected exception occurs upon the discovery of Storage Pools |
SI-371 | IBM DS8000 (REST): Lookup value is erroneously displayed as System Name |
Storage Intelligence 28
4 Changes - Released 2024-05-15What's New
ID | Description |
---|---|
SI-327 | Added support for Dell EMC PowerProtect DD (REST) |
Changes and Improvements
ID | Description |
---|---|
SI-336 | IBM DS8000 (REST): The volume serial number (VOLSER) is added to the Storage Volume's name for better identification |
Fixed Issues
ID | Description |
---|---|
SI-364 | Pure Storage FlashArray (REST v2.4+): Collect failure when getting APIVersion |
SI-290 | HPE Primera (WBEM): The calculation of some metrics is modified to match the values displayed in Infosight |
Storage KM 1.8.00
2 Changes - Released 2024-05-03Changes and Improvements
ID | Description |
---|---|
SKM-310 | Parameters and Monitors Information is not displayed if their value cannot be retrieved |
Fixed Issues
ID | Description |
---|---|
SKM-315 | A NullPointerException is generated when monitoring NAS storage systems |
Storage Intelligence 27
6 Changes - Released 2024-05-02Changes and Improvements
ID | Description |
---|---|
SI-361 | Dell EMC PowerVault (REST): The CacheHitRatio metric for Controllers is more accurate |
SI-360 | Dell EMC PowerVault (REST): The LinkStatus metric for Ports is more accurate |
SI-359 | Dell EMC PowerVault (REST): Added Status and StatusInformation metrics to Ports |
Fixed Issues
ID | Description |
---|---|
SI-362 | Dell EMC PowerVault (REST): Collection failure when LinkSpeed cannot be retrieved |
SI-356 | Dell EMC PowerVault (REST): Collection failure caused by a JdbcSQLDataException |
SI-353 | NetApp StorageGRID (REST): Response Time values are displayed in seconds instead of milliseconds |
Storage Intelligence 26
2 Changes - Released 2024-04-15What's New
ID | Description |
---|---|
SI-329 | Added support for NetApp StorageGRID |
Fixed Issues
ID | Description |
---|---|
SI-343 | IBM DS8000 (REST) and Oracle ZFS (REST): The Link Status parameter is incorrectly reported |
Storage Intelligence 25
5 Changes - Released 2024-03-15What's New
ID | Description |
---|---|
SI-323 | Added support for IBM DS8000 Series (REST) |
Fixed Issues
ID | Description |
---|---|
SI-340 | Pure Storage FlashBlade (REST): Storage systems' size is wrong |
SI-337 | Oracle ZFS (REST): "Capacity", "Consumed Capacity Percentage" and "Available Capacity Percentage" metrics for file systems are not correct |
SI-333 | Pure Storage FlashBlade (REST): The "Consumed Capacity Percentage" metric for file systems is greater than 100% |
SI-331 | IBM DS888x (WBEM): Storage Pools and Storage Volumes are not discovered |
Storage KM 1.7.00
1 Changes - Released 2024-01-25Changes and Improvements
ID | Description |
---|---|
SKM-301 | The performance of the CollectionHub has been improved |
Storage Intelligence 24
2 Changes - Released 2023-12-18What's New
ID | Description |
---|---|
SI-310 | Added support for Oracle ZFS (REST) |
Fixed Issues
ID | Description |
---|---|
SI-320 | Huawei OceanStor (REST): Storage system's Available Capacity and Consumed Capacity metrics are missing when the storage system is in NAS mode |
Storage Intelligence 23
2 Changes - Released 2023-11-17What's New
ID | Description |
---|---|
SI-300 | Added support for Pure Storage FlashBlade (REST) storage systems |
Changes and Improvements
ID | Description |
---|---|
SI-316 | Dell EMC PowerMax v4 (REST): The Configured Capacity and Capacity metrics for Storage Pools are more accurate |
Storage KM 1.6.00
8 Changes - Released 2023-11-10Changes and Improvements
ID | Description |
---|---|
SKM-291 | Report thresholds via the "SKM_q; thresholdsReport(endpointList)" command |
SKM-281 | Report Device Name in TrueSight/BHOM (MetaFQDN) via the "SKM_q; endpointsInfo()" command |
SKM-277 | Web UI: Ability to enable debug for specific endpoints |
SKM-272 | Debug logs are compressed by default at the end of debug window |
Fixed Issues
ID | Description |
---|---|
SKM-289 | Incorrect thresholds are set on the Controllers' Status parameter |
SKM-280 | Devices are no longer created in TrueSight because the endpoint's MetaFQDN is no longer set |
SKM-276 | The Monitor Type of some PATROL classes' Containers are erroneously identified as Monitors instead of Containers |
SKM-235 | Remove the Count parameter from the SKM_FILESYSTEM_CONT class |
Storage Intelligence 22
1 Changes - Released 2023-11-06What's New
ID | Description |
---|---|
SI-296 | Added support for Dell EMC PowerMax v4 (REST) |
Storage Intelligence 21
1 Changes - Released 2023-10-16Changes and Improvements
ID | Description |
---|---|
SI-311 | HPE Primera (WBEM): Added a new metric to report the Queue Length value for Storage Volumes |
Storage Intelligence 20
4 Changes - Released 2023-09-18What's New
ID | Description |
---|---|
SI-268 | Added support for NetApp Filers based on ONTAP REST API |
SI-267 | Added support for NetApp Filers based on Active IQ Unified Manager REST API |
Fixed Issues
ID | Description |
---|---|
SI-301 | NetApp E-Series (REST): Some classes such as SKM_SYSTEM, SKM_PORT, SKM_CONTROLLER are not discovered or collected |
SI-293 | Dell EMC VMAX (REST): Reported values for Configured Capacity and Subscribed Capacity metrics do not match the values displayed in the Unisphere UI |
Storage Intelligence 19
5 Changes - Released 2023-07-18What's New
ID | Description |
---|---|
SI-278 | Added support for Fujitsu Eternus AF/DX series (REST) |
Fixed Issues
ID | Description |
---|---|
SI-292 | Dell EMC ScaleIO (REST): Some capacity metrics are not collected for storage systems, storage pools and storage volumes |
SI-285 | Dell EMC VMAX (REST) and Dell EMC Unity (REST): All volumes may not be collected |
SI-282 | Dell EMC PowerStore (REST): Values for Configured Capacity and Subscribed Capacity metrics are missing |
SI-279 | Huawei OceanStor (REST): Unable to collect data from physical disks with unknown type |
Storage Intelligence 18
1 Changes - Released 2023-05-11Fixed Issues
ID | Description |
---|---|
SI-270 | Huawei OceanStor (REST): Missing devices reported due to expired token |
Storage KM 1.5.00
8 Changes - Released 2023-05-11Changes and Improvements
ID | Description |
---|---|
SKM-264 | ClientTimeout default value is increased to 30 minutes |
SKM-259 | Disable Missing Device Detection can be activated from a CMA policy |
SKM-258 | Added two configuration variables to customize queries retry delays |
Fixed Issues
ID | Description |
---|---|
SKM-262 | Vulnerability CVE-2021-44832 in SI Launcher |
SKM-257 | An incorrect threshold is set on the Present parameter of Controllers |
SKM-250 | Dell EMC VMAX (WBEM): Monitors are incorrectly attached to the SMI-S provider device instead of the storage system |
SKM-243 | IBM DS888x (WBEM) and Dell EMC VMAX (WBEM): The Status parameter are always set to 1 (Degraded) |
SKM-221 | Huawei OceanStor (REST): Missing and null objects are visible |
Storage Intelligence 17
6 Changes - Released 2023-04-14What's New
ID | Description |
---|---|
SI-260 | Added support for Hitachi GUM (REST) |
SI-242 | Added support for Scality Ring (REST) |
SI-217 | Added support for Hitachi E Series (REST) |
Fixed Issues
ID | Description |
---|---|
SI-269 | Dell EMC PowerStore (REST) stops working after the REST API is upgraded to v.3.x |
SI-265 | Dell EMC Isilon (REST): Storage Pools IDs are not unique |
SI-258 | Dell EMC VMAX (REST): Unisphere v10 is not supported |
Storage Intelligence 16
1 Changes - Released 2023-02-20Fixed Issues
ID | Description |
---|---|
SI-262 | Dell EMC Isilon (REST): Volume IDs are not unique |
Storage Intelligence 15
3 Changes - Released 2023-01-19What's New
ID | Description |
---|---|
SI-237 | HPE Primera (WBEM): Full support for HPE Primera and HP 3PAR StoreServ systems |
Changes and Improvements
ID | Description |
---|---|
SI-207 | Dell EMC SC Series (REST): Added the possibility to migrate from Dell Compellent ETL to Storage All In One ETL |
Fixed Issues
ID | Description |
---|---|
SI-240 | Dell EMC VMAX (REST): Connection times out while collecting volumes' metrics |
Storage KM 1.4.01
1 Changes - Released 2022-11-14Fixed Issues
ID | Description |
---|---|
SKM-239 | Security vulnerability in Swagger UI (OpenAPI) when displaying the documentation through Monitoring Studio |
Storage Intelligence 13
1 Changes - Released 2022-11-10Changes and Improvements
ID | Description |
---|---|
SI-236 | Dell EMC PowerVault (REST): Add the ability to enable hardware monitoring |
Storage KM 1.4.00
4 Changes - Released 2022-09-26Changes and Improvements
ID | Description |
---|---|
SKM-231 | Operation timeout is now configurable via the SI Launcher |
SKM-227 | Discovery timeout is customizable via the "endpointSiliciumLockTimeout" variable (Default increased to 3600 seconds) |
SKM-226 | Pure Storage FlashArray Series (REST v2.4+): Added token authentication to enable Hardware monitoring |
SKM-218 | Storage Analyzer KM now handles File Systems |
Storage Intelligence 12
11 Changes - Released 2022-09-22What's New
ID | Description |
---|---|
SI-211 | Added support for Dell EMC PowerVault (REST) |
Changes and Improvements
ID | Description |
---|---|
SI-226 | Dell EMC PowerStore (REST) and Dell EMC Unity (REST) require version 1.10.00 or higher of the Storage All-in-One engine |
SI-215 | Pure Storage (REST): Capacity to manage environments with more than 500 monitored volumes |
SI-201 | Dell EMC Unity (REST): Addition of new metrics for Storage Systems, Storage Pools and Storage Volumes |
Fixed Issues
ID | Description |
---|---|
SI-229 | Dell EMC SC Series (REST): Data collect is stopped when the REST API encounters a volume with a missing name |
SI-227 | Huawei OceanStor (REST): A NullPointerException is triggered when no iSCSI port is reported |
SI-222 | NetApp E-Series (REST): Discovery failure caused by HTTPResponseException or JdbcSQLSyntaxErrorException |
SI-221 | Dell EMC VMAX (REST): Controllers' Processor Utilization reports values higher than 100 % |
SI-209 | Pure Storage FlashArray (REST v2.4+): "OutOfMemoryError: GC overhead limit exceeded" causes the data collect to fail |
SI-206 | Dell EMC Isilon (REST): Processor Utilization (%) on Controllers reports values above 100 % |
SI-195 | Hitachi G Series (REST): A NullPointerException is triggered when no iSCSI port is reported |
Storage Intelligence 10
3 Changes - Released 2022-03-23What's New
ID | Description |
---|---|
SI-84 | Added support for Dell EMC PowerStore (REST) |
Fixed Issues
ID | Description |
---|---|
SI-197 | Dell EMC VMAX (REST): Data collection for volumes may fail when multiple systems are attached to the same Dell EMC Unisphere |
SI-191 | Dell EMC SC Series (REST): "HTTP Error 204"causes the adapter to stop discovering the Storage Systems |
Storage Intelligence 9
6 Changes - Released 2022-02-18What's New
ID | Description |
---|---|
SI-190 | Added support for Dell EMC PowerFlex/ScaleIO (REST) |
SI-180 | Added support for Dell EMC Unity (REST) |
Changes and Improvements
ID | Description |
---|---|
SI-192 | H2 database upgraded from v1.4.199 to v2.1.210 |
SI-186 | Jackson library upgraded to version 2.13.1 |
SI-182 | Remote systems are no longer supported for Dell EMC VMAX/PowerMax (REST) |
Fixed Issues
ID | Description |
---|---|
SI-179 | Dell EMC SC Series (REST): Port discovery fails due to an empty Speed string |
Storage KM 1.3.00
2 Changes - Released 2021-12-22Changes and Improvements
ID | Description |
---|---|
SKM-216 | Log4Shell Vulnerability: Update log4j version to 2.17.0 in the troubleshooting tool |
SKM-211 | Agent-side collection can be deactivated from the monitoring policy |
Storage Intelligence 8
6 Changes - Released 2021-08-26What's New
ID | Description |
---|---|
SI-163 | Added support for Huawei OceanStor (REST) |
Changes and Improvements
ID | Description |
---|---|
SI-176 | Replace Helix Capacity Optimization with Helix Continuous Optimization |
Fixed Issues
ID | Description |
---|---|
SI-167 | Dell EMC SC Series (REST): Cannot connect directly to the Dell EMC SC Series systems |
SI-166 | Hitachi G-Series (REST): Storage systems are not created as separate devices in TrueSight/Helix OM |
SI-165 | Dell EMC VMAX (REST): Storage systems are not created as separate devices in TrueSight/Helix OM |
SI-164 | Dell EMC VMAX (REST): Discovery fails when the number of volumes is lower than 1000 |
Storage Intelligence 7
1 Changes - Released 2021-04-22Changes and Improvements
ID | Description |
---|---|
SI-160 | Ceph Adapter: Added Vendor information to the Storage System properties (Storage Box) |
Storage Intelligence 6
5 Changes - Released 2021-03-15What's New
ID | Description |
---|---|
SI-129 | Added support for Pure Storage REST API v2.4+ |
SI-107 | Added support for Dell EMC VMAX/PowerMax (REST) |
SI-68 | Added support for Hitachi G Series (REST) |
Fixed Issues
ID | Description |
---|---|
SI-149 | The Licence Count value for Dell EMC Isilon storage systems erroneously reports 0 |
SI-132 | Ceph Adapter: Errors 400 cause the collect to stop |
Storage KM 1.2.00
7 Changes - Released 2021-03-15Changes and Improvements
ID | Description |
---|---|
SKM-191 | The KM triggers an alarm on the Collection Status parameter when the Storage Intelligence Adapter and the KM versions are not compatible |
SKM-177 | SKM is delivered with Storage Intelligence Library version 6 |
SKM-175 | Ability to Hide Volumes |
SKM-173 | Add API Token choice for Endpoint Connection Credentials |
Fixed Issues
ID | Description |
---|---|
SKM-196 | Bad handling of white spaces in file paths prevents the KM to monitor Endpoints |
SKM-187 | The Storage Intelligence Adapter for existing Endpoint cannot be changed |
SKM-184 | Increased Port Number range in CMA Endpoint Policy |
Storage KM 1.1.00
13 Changes - Released 2020-11-04What's New
ID | Description |
---|---|
SKM-138 | Integrate hardware monitoring through the Hardware Sentry KM |
Changes and Improvements
ID | Description |
---|---|
SKM-160 | A specific Storage Intelligence Adapter can now be manually specified in the CMA interface |
SKM-155 | The default content of the events generated upon storage alerts refers to the device to which the object is attached |
SKM-152 | Instances of the SKM_SYSTEM class now create devices in TrueSight |
SKM-144 | Enable hardware monitoring is on for v1.0.00 endpoints, while it is not |
SKM-143 | Web UI: When editing an endpoint from console Enable Hardware Monitoring is not displayed |
SKM-142 | Web UI: Indicate that hardware monitoring is not possible when the storage platform has no matching connector |
SKM-141 | Web UI: Add a confirmation step before removing a host |
SKM-140 | Add source KM name to the Hardware Sentry collection |
SKM-139 | Automatic Hardware KM integration |
SKM-99 | Integrate Storage Analyzer KM with Hardware Sentry KM |
Fixed Issues
ID | Description |
---|---|
SKM-163 | Response Time parameter values not always accurate for Netapp-Solidfire-REST, DellEMC-VMAX-WBEM and IBM-DS8880-WBEM platforms |
SKM-151 | Instance properties are not displayed in Monitoring Studio Web UI for SKM endpoints |
Storage Intelligence 5
13 Changes - Released 2020-11-03What's New
ID | Description |
---|---|
SI-89 | Storage Intelligence Adapters contain hardware connector information in order to trigger hardware monitoring if configured by the user |
SI-74 | New metrics added to Storage Intelligence Adapters |
Changes and Improvements
ID | Description |
---|---|
SI-124 | Add support for IBM DS888x (WBEM) |
SI-111 | Rename Red Hat Ceph (REST) to Ceph (REST) |
SI-83 | NetApp SolidFire (REST): The controller's memory size should report the sum of all available memory values |
SI-80 | Update Red Hat Ceph Adapter |
SI-79 | Update Pure Storage Adapter |
SI-78 | Update NetApp SolidFire Adapter |
SI-77 | Update NetApp E-Series Adapter |
SI-76 | Update Dell EMC XtremIO Adapter |
SI-75 | Update VMAX Adapter |
SI-37 | Add monitoring metrics in IBM DS 888x .si file |
Fixed Issues
ID | Description |
---|---|
SI-55 | ScaleIO - Operations and Rate are not correcly computed |
Storage Intelligence 3
3 Changes - Released 2020-08-21Changes and Improvements
ID | Description |
---|---|
SI-81 | Add support for Dell EMC ScaleIO (REST) |
SI-53 | Add support for Dell EMC SC Series (REST) |
SI-14 | Add support for IBM Spectrum Scale (REST) |
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
No results.