Patches

P1652: Sun SPARC Servers (Prtpicl) - DisplayID and Fan Thresholds Improved

Jun 09, 2015
Patch for BMC Performance Manager Express for Hardware - Version(s) 2.7.26,2.7.28,2.9.00,2.9.10,2.9.20,2.9.25

Download File

Patch content

Connector for monitoring Sun SPARC servers using the PrtPicl Connector.

Should you install this patch?

Install this patch if you wish to have more descriptive sensor identifiers in Portal or if no thresholds appear for fan sensors.

What does it fix?

  • A smaller version of the device ID is now used for the display ID to enable easier sensor identification.
  • No thresholds appeared for fan sensors when LowWarningThreshold did not exist for fan instances. LowPowerOffThreshold will now be used whenever this situation occurs.

How to install the patch?

  1. Copy the following file to %RSM_HOME%\RSMxx\SEN_HW\hdf_2xxx\ on each RSM:
    • MS_HW_SunPrtpicl.hdf
  2. No further actions are required. The new component monitoring will be added at the next discovery.