Patches
P1680: LUNs Being Monitored As Local Physical Disks
Sep 03, 2015Patch for BMC Performance Manager Express for Hardware - Version(s) 2.9.00,2.9.10,2.9.20,2.9.25
Download File
Patch content
Connector for WMI - Disks
Should you install this patch?
Install this patch if you see LUNs being monitored as local physical disks.
What does it fix?
- If a Windows server had both LUNs and local non-RAID physical disks, then the WMI - Disks connector monitored both as local physical disks. LUNs will now be excluded from the monitoring.
- EMC PowerPath LUNs were monitored when local physical disks were missing.
How to install the patch?
- Copy the following file to %RSM_HOME%\RSMxx\SEN_HW\hdf_2xxx\ on each RSM:
- MS_HW_WBEMGenDiskNT.hdf
- No further actions are required. The new component monitoring will be added at the next discovery.