Patches

P1680: LUNs Being Monitored As Local Physical Disks

Sep 03, 2015
Patch for BMC Performance Manager Express for Hardware - Version(s) 2.9.00,2.9.10,2.9.20,2.9.25

Download File

Patch content

Connector for WMI - Disks

Should you install this patch?

Install this patch if you see LUNs being monitored as local physical disks.

What does it fix?

  • If a Windows server had both LUNs and local non-RAID physical disks, then the WMI - Disks connector monitored both as local physical disks. LUNs will now be excluded from the monitoring.
  • EMC PowerPath LUNs were monitored when local physical disks were missing.

How to install the patch?

  1. Copy the following file to %RSM_HOME%\RSMxx\SEN_HW\hdf_2xxx\ on each RSM:
    • MS_HW_WBEMGenDiskNT.hdf
  2. No further actions are required. The new component monitoring will be added at the next discovery.