Patches

P1682: Support for Cisco Ethernet Switches

Sep 03, 2015
Patch for BMC Performance Manager Express for Hardware - Version(s) 2.9.00,2.9.10,2.9.20,2.9.25

Download File

Patch content

Connector for Cisco Ethernet Switches

Should you install this patch?

Install this patch if you wish to monitor a Cisco Ethernet switch.

Note:

  • Cisco MDS Switches should be monitored using the Cisco MDS9000 Series - SSH/Telnet connector.
  • Cisco Nexus/UCS combined Fiber/Ethernet switches (FCoE) should be monitored using the Cisco UCS Manager (Blade, Fabric Interconnect Switch) connector.
  • What does it fix?

    Adds monitoring of the non-port components (power supplies, fans, temperature sensors and voltages) for Cisco Ethernet switches via SNMP.

    Note: Ports can be monitored using the MIB-2 Standard SNMP Agent - Network Interfaces connector.

    How to install the patch?

    1. Copy the following file to %RSM_HOME%\RSMxx\SEN_HW\hdf_2xxx\ on each RSM:
      • MS_HW_CiscoEthernetSwitch.hdf
    2. No further actions are required. The new component monitoring will be added at the next discovery.