Patches
P1684: Dell PowerEdge with Non-RAID Disks
Sep 03, 2015Patch for BMC Performance Manager Express for Hardware - Version(s) 2.9.00,2.9.10,2.9.20,2.9.25
Download File
Patch content
Connector for Dell OpenManage Storage Manager
Should you install this patch?
Install this patch if you have a Dell server with non-RAID disks.
What does it fix?
- Dell Servers with non-RAID disks could activate both the WMI - Disks and Dell OpenManage Storage Manager connectors, resulting in double monitoring.
- The Dell OpenManage Storage Manager connector failed to interpret the status of Non-RAID disks (reported as Unknown instead of OK)
How to install the patch?
- Copy the following file to %RSM_HOME%\RSMxx\SEN_HW\hdf_2xxx\ on each RSM:
- MS_HW_DellStorageManager.hdf
- No further actions are required. The new component monitoring will be added at the next discovery.