Patches

SWSY-2876: Multi-Parameter Formula Monitor Failure

Apr 04, 2017
Patch for Monitoring Studio KM for PATROL - Version(s) 9.3.00

Download File

Patch content

PSL libraries

Should you install this patch?

Install this patch if you use the Multi-Parameter Formula Monitor to process values extracted from the String Search, Numeric Value Extraction, or Text Transform Monitors.

What does it fix?

  • An issue preventing the collect of String Search, Numeric Value Extraction and Text Transform Monitor instances attached to a Multi-Parameter Formula Monitor instance.
  • A problem leading to String Search, Numeric Value Extraction and Text Transform Monitor instances not being properly copied nor deleted.

How to install the patch?

  1. Unzip SWSY-2876.zip
  2. Copy the following files to the $PATROL_HOME/lib/psl or %PATROL_HOME%\lib\psl directory on the server where the PATROL Agent runs:
    • SEN_MS_generic.lib
    • SEN_MS_kmcommands.lib
  3. Restart the PATROL Agent for the patch to take effect. Nothing needs to be installed on Console systems.