SWSY-2876: Multi-Parameter Formula Monitor Failure
Apr 04, 2017Patch for Monitoring Studio KM for PATROL - Version(s) 9.3.00
Download File
Patch content
PSL libraries
Should you install this patch?
Install this patch if you use the Multi-Parameter Formula Monitor to process values extracted from the String Search, Numeric Value Extraction, or Text Transform Monitors.
What does it fix?
- An issue preventing the collect of String Search, Numeric Value Extraction and Text Transform Monitor instances attached to a Multi-Parameter Formula Monitor instance.
- A problem leading to String Search, Numeric Value Extraction and Text Transform Monitor instances not being properly copied nor deleted.
How to install the patch?
- Unzip SWSY-2876.zip
- Copy the following files to the $PATROL_HOME/lib/psl or %PATROL_HOME%\lib\psl directory on the server where the PATROL Agent runs:
- SEN_MS_generic.lib
- SEN_MS_kmcommands.lib
- Restart the PATROL Agent for the patch to take effect. Nothing needs to be installed on Console systems.