Pure Storage System
PATROL Class: SEN_PURE_STORAGESYSTEM - Monitor Type: MONITOR - Monitor Category: System
CDM Class: BMC_ComputerSystem -- Instances of this monitor will be represented as devices in TrueSight Operations Management
Monitors a storage system.
Attributes (Parameters)
Name | PATROL Name | Units | Default Thresholds | Description |
---|---|---|---|---|
Available Capacity | AvailableCapacity | TB | None | Total capacity not consumed in the storage system. Type: Statistics |
Collection Status | CollectionStatus | 0 = OK 1 = Degraded 2 = Failed |
WARN ALARM |
Status of the collection. Type: Collection Status - Spikes expected |
Collection Status Information | CollectionStatusInformation | None | None | Detailed information about the collection status. Errors encountered by Storage System will be reported in this parameter. Type: Text |
Consumed Capacity | ConsumedCapacity | TB | None | Number of bytes actually consumed in the storage system. Type: Statistics |
Operation Rate | OperationRate | operations/s | None | Number of read operations per second. Type: KPI - Statistics - Spikes expected - Default graph |
Oversubscription Situation | OversubscriptionSituation | 0 = No 1 = Yes |
ALARM |
This parameter reports an oversubscription situation, that is when: 1.The storage pool is configured for thin provisioning ("thin storage pool") 2.The storage pool is oversubscribed, i.e. the total disk space visible to the hosts (subscribers) is greater than its actual capacity (this situation is normal for a thin pool since it is its very purpose) 3.The storage pool actual consumed capacity is nearing 100% Such situation is highly critical because the inability to allocate additional space to a LUN when requested by the subscriber host will lead to catastrophic data loss and corruption. Type: Statistics - Spikes expected |
Port Count | PortCount | Ports | None | Number of ports. Type: Statistics |
Read Byte Rate | ReadByteRate | MB/s | None | Number of read bytes per second performed by the storage system. Type: Statistics - Spikes expected |
Read Operation Rate | ReadOperationRate | operations/s | None | Number of read operations per second performed by the storage system. Type: Statistics - Spikes expected |
Read Response Time | ReadResponseTime | ms | WARN |
Average response time for read operations. Type: Response Time - Spikes expected |
Response Time | ResponseTime | ms | WARN |
Average response time for all operations. Type: Response Time - Spikes expected |
Status | Status | 0 = OK 1 = Degraded 2 = Failed |
WARN ALARM |
Status of the storage system. Type: Availability - Spikes expected |
Status Information | StatusInformation | None | None | Detailed information about the storage system status. Type: Text |
Subscribed Capacity | SubscribedCapacity | TB | None | Number of terabytes reserved in the storage system. Type: Statistics |
Transfer Byte Rate | TransferByteRate | MB/s | None | Total bytes read and written per second to the storage system. Type: KPI - Statistics - Spikes expected - Default graph |
Write Byte Rate | WriteByteRate | MB/s | None | Bytes written per second to the storage system since the last collect. Type: Statistics - Spikes expected |
Write Operation Rate | WriteOperationRate | operations/s | None | Number of write operations per second. Type: Statistics - Spikes expected |
Write Response Time | WriteResponseTime | ms | WARN |
Average response time for write operations. Type: Response Time - Spikes expected |
Infoboxes (PATROL Console Only)
Name | Description |
---|---|
PATROL ID | The PATROL internal identifier. |
Software Version | Software version of the storage system. |
Serial Number | Unique identifier of the storage system. |
Model | Model of the storage system. |
Revision | Revision of the storage system. |
Array Name | Name of the storage system. |
Number of Disks | Number of flash modules. |
Size | Size of the storage system. |
Capacity | Capacity of the storage system. |
FQDN | Fully Qualified Domain Name of the storage system. |
MetaEntityType | System model, updated upon each discovery cycle (typically: Storage.PureStorage). |
Menu Commands (PATROL Console Only)
Menu Command | Description |
---|---|
Edit Connection Settings... | Enables you to edit the connection settings to the selected Pure Storage system. |
Reporting > Storage System Activity... | Enables you to generate a report on the storage system activity. |
Reporting > Volumes Activity... | Enables you to generate a report on volumes activity. |
Reporting > LUNs Mapping Table... | Enables you to generate a report listing mapped and unmapped LUNs. |
Reporting > Per Host Storage Allocation | Enables you to generate a report on the volume of storage allocated to each monitored host. |
Reporting > Per LUN Storage Allocation | Enables you to generate a report on the volume of storage allocated to each monitored LUN. |
Search WWN/IQN... | Enables you to find any component based on its complete or partial World Wide Name or IQN. |
Discovery Interval... | Enables you to customize the discovery cycle. By default, discovery is performed every hour. |
Polling Interval... | Enables you to customize the polling cycle. By default, polling is performed every 2 minutes. |
Disable Volumes Monitoring... | Disables the monitoring of all the volumes of a system. |
Pause Monitoring | Pauses the monitoring of the selected object. |
Resume Monitoring | Resumes the monitoring of the selected object. |
Remove | Removes the selected object from the monitoring environment. |
Refresh Parameters | Refreshes all parameters of the application class. |
storage pure km patrol