HC-281-KM - SMI-S Raid Controllers - Devices Erroneously Discovered as Controllers
Jul 06, 2016Download File
Patch content
Connectors for:
- SMI-S Compliant RAID Controller - Linux
- SMI-S Compliant RAID Controller - Windows
Should you install this patch?
Install this patch if you are seeing non-controller devices displayed as disk controllers.
What does it fix?
The connector now verifies that each controller has associated physical disks to prevent non-controllers devices from being falsely reported as controllers.
How to install the patch?
- Copy the following files the %PATROL_HOME%\lib\MS_HW_hdf or $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
- MS_HW_Director52ServeRAIDLinux.hdf
- MS_HW_Director52ServeRAIDNT.hdf
- Re-initialize Hardware Sentry for the patch to take effect. Nothing needs to be installed on Console systems.