Patches

P1023 - MS_HW_SunPrtdiag.hdf

Jun 15, 2007
Patch for Hardware Sentry KM for PATROL - Version(s) 1.4.00

Download File

Patch content

Hardware Sentry connector for Sun Solaris - Environment

Should you install this patch?

Apply this patch if you are using Hardware Sentry on a Sun SPARC-based server.

What does it fix?

This patch fixes the following problems:
- Faulty processors were improperly reported with an "unknown status"
- Monitored components were randomly marked as "missing" on some systems (because the prtdiag command sometimes took more than 30 seconds to complete)

How to install the patch?

Install the MS_HW_SunPrtdiag.hdf file in the $PATROL_HOME/lib/MS_HW_hdf directory of the managed server. Re-initialize Hardware Sentry for the patch to take effect. Nothing needs to be installed on Console systems.