Patches

P1052 - SW_sentry_numbers.lib

Mar 20, 2008
Patch for Monitoring Studio KM for PATROL - Version(s) 8.5.01

Download File

Patch content

Monitoring Studio KM Numeric Value Extraction library

Should you install this patch?

Apply this patch if you use a regular expression to identify the line containing the number to extract.

What does it fix?

Monitoring Studio did not clearly identify the lines matching the regular expression and all lines were taken into account when searching for the Numeric Value to extract. This issue was introduced in v8.5.00.

How to install the patch?

Install the SW_sentry_numbers.lib file in the %PATROL_HOME%\lib\psl directory of the managed server. Restart the PATROL Agent for the patch to take effect. Nothing needs to be installed on Console systems.

Warning! Once the file is installed, the KM stops working until the PATROL Agent has been reinitialized.