Patches

P1074 - Patch for HP ProLiant servers

Jan 30, 2009
Patch for Hardware Sentry KM for PATROL - Version(s) 1.5.01

Download File

Patch content

Connectors for Hardware Sentry KM to monitor HP/Compaq StorageWorks external disk arrays and HP/Compaq HBAs

Should you install this patch?

Apply this patch if you are using Hardware Sentry to monitor HP ProLiant servers attached to an external HP StorageWorks disk array.

What does it fix?

This bundle of connectors fixes an issue that was introduced in version 1.5.00 of the KM. Since version 1.5.00, the KM was no longer able to detect and monitor SCSI-attached (non-Fiber) HP StorageWorks disk arrays. When upgraded from 1.4.00, the icons corresponding to the disk array were marked as missing and in alarm. There are now two separate connectors to support the HBAs and the disk arrays.

How to install the patch?

Copy the following files in the $PATROL_HOME/lib/MS_HW_hdf directory on the managed server:
- MS_HW_CpqFCADriveArray.hdf
- MS_HW_CpqHBA.hdf
Reinitialize the KM for the patch to take effect ([right-click] on the main Hardware Sentry icon > [KM Commands] > [Reinitialize KM�] with the default options).