Patches

P1151: Patch for IBM EXP3000 External Bays (Linux)

June 17, 2010
Patch for Hardware Sentry KM for PATROL - Version(s) 1.6.00, 1.6.01

This patch is replaced with !

 Download

Patch content

Connectors for MegaCli (LSI) managed RAID card

Should you install this patch?

Apply this patch if you have an IBM EXP 3000 disk enclosure connected to your Linux Server.

What does it fix?

Disks in an external IBM EXP 3000 drive enclosure (directly attached to the server) were not taken into account in the monitoring of Linux servers.
This was caused by the IBM Director Agent with ServeRaid extensions which failed to report on the disks connected to ServeRAID controller but located in an external drive enclosure.

The product now uses MegaCli instead of the IBM Director Agent to collect information about the physical disks located inside the IBM EXP 3000 drive enclosure.

How to install the patch?

Copy the following files to the $PATROL_HOME/lib/MS_HW_hdf directory on the managed server:

  • MS_HW_SunMegaCli.hdf
MegaCli needs to be installed and in the $PATH of the system and requires root privileges (requires root credentials specified in the KM / sudo setup for MegaCli).

Re-initialize Hardware Sentry for the patch to take effect.