Patches

P1242: Collection Errors with Deactivated Parameters

Sep 29, 2011
Patch for Hardware Sentry KM for PATROL - Version(s) 1.7.00, 1.7.01

This patch is replaced with !

 Download

Patch content

PSL library for Hardware Sentry KM for PATROL

Should you install this patch?

Apply this patch if during the collection process you get an error message of type "No collect value available".

What does it fix?

An error message of type "No collect value available" was displayed when trying to collect information that was not available.

How to install the patch?

  1. Copy the following file to the %PATROL_HOME%\lib\psl or $PATROL_HOME/lib/psl directory on the managed server:
    • MS_HW_generic.lib
  2. Restart the PATROL Agent for the patch to take effect. Nothing needs to be installed on Console systems.