Patches

P1380: Enabling WBEM and SSL Connections on IBM AIX and HP Servers

January 15, 2013
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.00

This patch is replaced with !

 Download

Patch content

Library files for the Hardware Sentry Collection Hub

Should you install this patch?

Install this patch on IBM AIX and HP servers if you wish to monitor remote UNIX/Linux servers via SSH or use WBEM-based commands to monitor storage systems with Hardware Sentry KM for PATROL 1.8.00.

What does it fix?

This patch enables WBEM and SSH requests on IBM AIX and HP servers running Hardware Sentry KM for PATROL 1.8.00.

How to install the patch?

  1. Copy the following file to the $PATROL_HOME/lib/psl or %PATROL_HOME%\lib\psl directory on the server where the PATROL Agent runs:
    • MS_HW_matsya.lib
  2. Restart the PATROL Agent for the patch to take effect.
  3. Nothing needs to be installed on Console systems.

    Warning: The monitoring stops working immediately after the PSL library has been installed and until the PATROL Agent has been restarted.