P1575: DiskPart Connector Causes Thread, Handle Leak in VDS.EXE on Windows

Oct 29, 2014
Patch for BMC Performance Manager Express for Hardware - Version(s) 2.7.26, 2.7.28, 2.9.00, 2.9.10, 2.9.20

This patch is replaced with !

 Download

Patch content

Connector for "Windows - DiskPart"

Should you install this patch?

Apply this patch in case of a thread and handle leak in the VDS.EXE process, which can cause the corresponding service to crash.

What does it fix?

A bug in DISKPART.EXE leaves open threads in VDS.EXE when commands are piped in the command line. The ECHO LIST VOLUME|DISKPART was replaced to make sure the EXIT command is executed and the thread terminated.

How to install the patch?

  1. Copy the following file to %RSM_HOME%\RSMxx\SEN_HW\hdf_2xxx\on each RSM:
    • MS_HW_DiskPart.hdf
  2. No further actions are required. The new component monitoring will be added at the next discovery.