P1605: Monitoring HP P2000 G3 MSA Array Systems via WBEM

Feb 05, 2015
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.00, 1.8.01, 1.8.02, 1.9.00

This patch is replaced with !

 Download

Patch content

Connector for HP P2000 G3 or later (WBEM)

Should you install this patch?

Install this patch if you wish to monitor your HP P2000 G3 MSA Array Systems via WBEM instead of SSH.

What does it fix?

This patch provides:

  • an alternative monitoring method for HP P2000 G3 MSA Array Systems. Please note that this patch will not work on G1 or G2 systems.
  • a more reliable and efficient method (WBEM) to monitor HP P2000 G3 MSA Array systems.

How to install the patch?

  1. Copy the following file to the $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_HPP2000WBEM.hdf
  2. Re-initialize Hardware Sentry.
  3. Provide WBEM Credentials for the new connector.
  4. Nothing needs to be installed on Console systems.
The successful activation of this connector will automatically disable the SSH based monitoring method.