Patches

P1666: HP ProLiant: Improved Power Consumption Monitoring

July 15, 2015
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.00, 1.8.01, 1.8.02, 1.9.00

This patch is replaced with !

 Download

Patch content

Connector for HP Insight Management Agent - Server

Should you install this patch?

Install this patch if the power consumption parameter returns no value.

What does it fix?

When HP servers did not return an overall power consumption, the KM disabled the corresponding parameter and made an estimate in the capacity report. When this information is not available, the connector will now try to sum up the power consumption of all power supplies before falling back on the estimate.

How to install the patch?

  1. Copy the following file to the $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_CpMgServNT.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect. Nothing needs to be installed on Console systems.