Patches

P1679: LUNs Being Monitored As Local Physical Disks

September 3, 2015
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.00, 1.8.01, 1.8.02, 1.9.00

This patch is replaced with !

 Download

Patch content

Connector for WMI - Disks

Should you install this patch?

Install this patch if you see LUNs being monitored as local physical disks.

What does it fix?

  • If a Windows server had both LUNs and local non-RAID physical disks, then the WMI - Disks connector monitored both as local physical disks. LUNs will now be excluded from the monitoring.
  • EMC PowerPath LUNs were monitored when local physical disks were missing.

How to install the patch?

  1. Copy the following file to the $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_WBEMGenDiskNT.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect.
  3. Nothing needs to be installed on Console systems.