Monitoring Configuration

To collect metrics from your targets, you need to provide the following information to Hardware Sentry OpenTelemetry Collector:

  • the hostname of the target to be monitored
  • its type
  • the protocol to be used.

This information must be provided in the config/hws-config.yaml file (an alternate path can be specified in otel-config.yaml).

The YAML syntax of the configuration file must be strictly respected for Hardware Sentry OpenTelemetry Collector to operate correctly (notably the indentation). As changes in this file are taken into account immediately, there is no need to restart the OpenTelemetry Collector.

Monitored Targets

Systems to monitor are defined under targets with the below syntax:

targets:

- target:
    hostname: <hostname>
    type: <target-type>
  <protocol-configuration>

where:

Protocols and Credentials

HTTP

Use the parameters below to configure the HTTP protocol:

Parameter Description
http Protocol used to access the target.
port The HTTPS port number used to perform SNMP queries (Default: 443).
username Name used to establish the connection with the target via the HTTP protocol.
password Password used to establish the connection with the target via the HTTP protocol.

Example

targets:

  - target:
      hostname: myhost-01
      type: storage
    http:
      https: true
      port: 443
      username: myusername
      password: mypwd

IPMI

Use the parameters below to configure the IPMI protocol:

Parameter Description
ipmi Protocol used to access the target.
username Name used to establish the connection with the target via the IPMI protocol.
password Password used to establish the connection with the target via the IPMI protocol.

Example

targets:

- target:
    hostname: myhost-01
    type: oob
  ipmi:
    username: myusername
    password: mypwd

OS Commands

Use the parameters below to configure OS Commands:

Parameter Description
osCommand Protocol used to access the target.
timeout How long until the local OS Commands time out (default: 120s). See Configuring Timeout Durations for available options.
useSudo Whether sudo is used or not for the local OS Command (true or false).
useSudoCommands List of commands for which sudo is required.
sudoCommand Sudo command to be used (Default: sudo).

Example

targets:
  - target:
      hostname: myhost-01
      type: linux
    osCommand:
      timeout: 120
      useSudo: true
      useSudoCommands: [ cmd1, cmd2 ]
      sudoCommand: sudo

SSH

Use the parameters below to configure the SSH protocol:

Parameter Description
ssh Protocol used to access the target.
timeout How long until the command times out (default: 120s).
useSudo Whether sudo is used or not for the SSH Command (true or false).
useSudoCommands List of commands for which sudo is required.
sudoCommand Sudo command to be used (Default: sudo).
username Name to use for performing the SSH query.
password Password to use for performing the SSH query.
privateKey Private Key File to use to establish the connection to the host through the SSH protocol

Example

targets:
  - target:
      hostname: myhost-01
      type: linux
    ssh:
      timeout: 120
      useSudo: true
      useSudoCommands: [ cmd1, cmd2 ]
      sudoCommand: sudo
      username: myusername
      password: mypwd
      privateKey: /tmp/ssh-key.txt

SNMP

Use the parameters below to configure the SNMP protocol:

Parameter Description
snmp Protocol used to access the target.
version The version of the SNMP protocol (v1, v2c, v3-no-auth, v3-md5, v3-sha).
community The SNMP Community string to use to perform SNMP v1 queries (Default: public).
port The SNMP port number used to perform SNMP queries (Default: 161).
timeout How long until the SNMP request times out (default: 120s).
privacy SNMP v3 only - The type of encryption protocol (none, aes, des).
privacy password SNMP v3 only - Password associated to the privacy protocol.
username SNMP v3 only - Name to use for performing the SNMP query.
password SNMP v3 only - Password to use for performing the SNMP query.

Example

targets:

- target:
    hostname: myhost-01
    type: linux
  snmp:
    version: v1
    community: public
    port: 161
    timeout: 120s

- target:
    hostname: myhost-01
    type: linux
  snmp:
    version: v2c
    community: public
    port: 161
    timeout: 120s

- target:
    hostname: myhost-01
    type: linux
  snmp:
    version: v3-md5
    community: public
    port: 161
    timeout: 120s
    privacy: des
    privacyPassword: myprivacypwd
    username: myusername
    password: mypwd

WBEM

Use the parameters below to configure the WBEM protocol:

Parameter Description
wbem Protocol used to access the target.
protocol The protocol used to access the target.
port The HTTPS port number used to perform WBEM queries (Default: 5989 for HTTPS or 5988 for HTTP).
timeout How long until the WBEM request times out (default: 120s).
username Name used to establish the connection with the target via the WBEM protocol.
password Password used to establish the connection with the target via the WBEM protocol.

Example

targets:

  - target:
      hostname: myhost-01
      type: storage
    wbem:
      protocol: HTTPS
      port: 5989
      timeout: 120s
      username: myusername
      password: mypwd

WMI

Use the parameters below to configure the WMI protocol:

Parameter Description
wmi Protocol used to access the target.
timeout How long until the WMI request times out (default: 120s).
username Name used to establish the connection with the target via the WMI protocol.
password Password used to establish the connection with the target via the WMI protocol.

Example

targets:

  - target:
      hostname: myhost-01
      type: WIN
    wmi:
      timeout: 120s
      username: myusername
      password: mypwd

Site and Sustainable IT Settings

You can specify additional labels to be added to each collected metric, with the extraLabels property:

extraLabels:
  site: Datacenter 1 # Customize with your own site naming (dedicating 1 collector to 1 site is a good practice)
  label_name: "Label Value"

This is an easy way to add a label to all metrics collected by this instance of the Hardware Sentry OpenTelemetry Collector. We recommend that you run at least one separate instance of the OpenTelemetry Collector for each site, and specify a different site label value for each of them. This will be particularly useful to group monitored systems per their physical location.

Similarly, you can specify additional static metrics to be exposed with the extraMetrics property:

extraMetrics:
  hw_carbon_density_grams: 350 # in g/kWh -- 350g/kWh is the average in Europe
  hw_electricity_cost_dollars: 0.12 # in $/kWh -- $0.12/kWh is the average for non-household in Europe
  hw_pue_ratio: 1.8

The above example configures the OpenTelemetry Collector to expose the carbon density and price per kWh of the electricity in the monitored site. These metrics can be leveraged in Grafana dashboards to calculate the carbon footprint, with different carbon densities for each monitored site, for example.

Other Configuration Settings

Timeout, Duration and Period Format

Timeouts, durations and periods are specified with the below format:

Unit Description Examples
s seconds 120s
m minutes 90m, 1m15s
h hours 1h, 1h30m
d days (based on a 24-hour day) 1d

Collect Period

By default, Hardware Sentry OpenTelemetry Collector collects metrics from the monitored targets every minute. To change the default collect period:

  • for all your targets, add the collectPeriod parameter just before the targets section:

    collectPeriod: 2m
    
    targets: # ...
    
  • for a specific target, add the collectPeriod parameter in the relevant target section:

    targets:
    
    - target:
        hostname: myhost
        type: linux
      snmp:
        version: v1
        community: public
        port: 161
        timeout: 120s
      collectPeriod: 1m30s # Customized
    

There is a decorelation between the internal collect period and the scrape interval configured in config/otel-config.yaml. You need to make sure the internal collect period is shorter than the scrape interval to avoid gaps or duplicate points, which would affect rate calculations.

Collecting metrics too frequently can cause CPU-intensive workloads.

Discovery Cycle

Hardware Sentry OpenTelemetry Collector periodically performs discoveries to detect new components in your monitored environment. By default, Hardware Sentry OpenTelemetry Collector runs a discovery after 30 collects. To change this default discovery cycle:

  • for all your targets, add the discoveryCycle just before the targets section:

    discoveryCycle: 15
    
    targets: # ...
    
  • for a specific target, add the discoveryCycle parameter in the relevant target section:

    targets:
    
    - target:
        hostname: myhost
        type: linux
      snmp:
        version: v1
        community: public
        port: 161
        timeout: 120s
      discoveryCycle: 5 # Customized
    

and indicate the number of collects after which a discovery will be performed.

Running discoveries too frequently can cause CPU-intensive workloads.

Job Pool Size

By default, Hardware Sentry OpenTelemetry Collector runs up to 20 discovery and collect jobs in parallel. To increase or decrease the number of jobs Hardware Sentry OpenTelemetry Collector can run simultaneously, add the jobPoolSize parameter just before the targets section:

jobPoolSize: 20

targets: # ...

and indicate a number of jobs.

Running too many jobs in parallel can lead to an OutOfMemory error.

Force or Exclude Connectors

The Hardware Sentry OpenTelemetry Collector comes with the Hardware Connector Library, a library that consists of hundreds of hardware connectors that describe how to discover hardware components and detect failures. When running Hardware Sentry OpenTelemetry Collector, the connectors are automatically selected based on the device type provided and the enabled protocols. You can however indicate to Hardware Sentry OpenTelemetry Collector which connectors should be used or excluded.

Use the parameters below to select or exclude connectors:

Parameter Description
selectedConnectors Connector(s) to use to monitor the target. No automatic detection will be performed.
excludedConnectors Connector(s) that must be excluded from the automatic detection.

Connector names must be comma-separated, as shown in the example below:

targets:

  - target:
      hostname: myhost-01
      type: WIN
    wmi:
      timeout: 120s
      username: myusername
      password: mypwd
    selectedConnectors: [ VMwareESX4i, VMwareESXi ]
    excludedConnectors: [ VMwareESXiDisksStorage ]

The exhaustive list of connectors is available in the Hardware Connector Library User Documentation<. The list of connectors in the current installation of Hardware Sentry OpenTelemetry Collector can be obtained with the below command:

$ hws -l

More information on the hws command