Back to the list of connectors

Cisco Entity Sensor (SNMP)

Connector file name: MS_HW_CiscoEntitySensor.hdf

This connector supersedes:

Description

This connector discovers the enclosure and Ethernet ports of a system equipped with an MIB-2 standard SNMP Agent.

Target

Typical platform: Cisco

Operating system: Network Device

Prerequisites

Leverages: MIB-2 Standard SNMP Agent

Technology and protocols: SNMP

Connector Activation Criteria

The Cisco Entity Sensor (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.9.9.91.1.1.1.1 must return a value in the same subtree
  • An SNMP Get-Next on the OID 1.3.6.1.2.1.47.1.1.1.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Serial Number
  • Type
  • Vendor
  • Power Consumption
Fan (MS_HW_FAN)
    • Speed
    • Status
    Network Card, FC Port (MS_HW_NETWORK)
    • Device Type
    • Physical Address
    • Physical Address Type
    • Bandwidth Utilization
    • Error Percent
    • Link Speed
    • Link Status
    • Received Bytes Rate
    • Received Packets Rate
    • Status
    • Transmitted Bytes Rate
    • Transmitted Packets Rate
    Power Supply (MS_HW_POWERSUPPLY)
    • Additional Information 1
    • Additional Information 2
    • Additional Information 3
    • Status
    Temperature Sensor (MS_HW_TEMPERATURE)
      • Status
      • Temperature
      Voltage Sensor (MS_HW_VOLTAGE)
      • Voltage Type
      • Status
      • Voltage
      Keywords:
      hardware hdf patrol connectors