Back to the list of connectors
SMI-S Compliant Disk Arrays
Connector file name: MS_HW_SMISDiskArray.hdf
This connector is superseded by:
- MS_HW_HitachiVSPSNMP.hdf
- MS_HW_FujitsuEternus.hdf
- MS_HW_Director52ServeRAIDLinux.hdf
- MS_HW_IBMDS68DiskArray.hdf
- MS_HW_HitachiDiskArray.hdf
- MS_HW_IBMxcli.hdf
- MS_HW_HitachiVSPDiskArray.hdf
- MS_HW_EMCDiskArray.hdf
- MS_HW_HP3PAR.hdf
- MS_HW_HPSSSU.hdf
- MS_HW_HPSSSU-Linux.hdf
Description
This connector discovers the enclosure and the disks of SAN disk arrays, as well as the storage pools and storage volumes. It will also discover and monitor the FC ports of the array and the various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.
Target
Typical platform: Any SMI-S compliant disk array
Operating system: Storage System
Prerequisites
Leverages: SMI-S Agent provided by the array vendor
Technology and protocols: WBEM
Connector Activation Criteria
The SMI-S Compliant Disk Arrays connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic
- WQL Query:
SELECT Name,Dedicated FROM CIM_ComputerSystem
- Result contains:
[;|]3|[0-9|]*;$
(regex)
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic
- WQL Query:
SELECT DeviceID FROM CIM_DiskDrive
- Namespace:
Monitors
Object Type | Discovered Properties | Collected Parameters |
---|---|---|
Enclosure (MS_HW_ENCLOSURE) |
|
|
Fan (MS_HW_FAN) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
Network Card, FC Port (MS_HW_NETWORK) |
|
|
Other Device (MS_HW_OTHERDEVICE) |
|
|
Physical Disk (MS_HW_PHYSICALDISK) |
|
|
Power Supply (MS_HW_POWERSUPPLY) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE) |
|
|