Back to the list of connectors

HP BladeSystem

Description

This connector provides hardware monitoring for the HP BladeSystem racks through the HP Insight Management Agents.

Connector ID: HPBladeSystem

This connector is superseded by:

Target

Typical platform: HP BladeSystem

Operating systems: Out-of-Band, Microsoft Windows, Linux, Oracle Solaris

Prerequisites

Leverages: HP iLO / HP Insight Management Agents

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t management -f HPBladeSystem --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ HPBladeSystem ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The HP BladeSystem connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.232.22.2.3.1.1.1.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.enclosure.energy
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • type
  • vendor
Blade
  • hw.blade.power_state{state="on|off|suspended"}
  • hw.status{hw.type="blade",state="ok|degraded|failed"}
  • hw.status{hw.type="blade",state="present"}
  • model
  • blade_name
  • serial_number
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • sensor_location
Other Device
  • hw.status{hw.type="other_device",state="ok|degraded|failed"}
  • hw.status{hw.type="other_device",state="present"}
  • device_type
Power Supply
  • hw.power_supply.limit{limit_type="max"}
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
    Temperature Sensor
    • hw.status{hw.type="temperature",state="ok|degraded|failed"}
    • hw.status{hw.type="temperature",state="present"}
    • hw.temperature
    • hw.temperature.limit{limit_type="high.degraded"}
    • sensor_location
    No results.