IBM Netfinity Manager 5.20.x - Disks

Description

This connector provides IBM ServerRAID monitoring through the IBM Netfinity Manager Services SNMP sub-agent which supports almost all old IBM servers (Netfinity) under Windows.

Connector ID: IbmNetfinityManagerRAID

Target

Typical platform: IBM Netfinity

Operating system: Microsoft Windows

Prerequisites

Leverages: IBM Netfinity Manager 5.20.x

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f IbmNetfinityManagerRAID --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ IbmNetfinityManagerRAID ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The IBM Netfinity Manager 5.20.x - Disks connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.2.6.71.200.1.1.38.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Disk Controller
  • hw.status{hw.type="disk_controller",state="present"}
  • model
  • vendor
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
    Physical Disk
    • hw.physical_disk.size
    • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="physical_disk",state="present"}