Number of errors that prevent Monitoring Studio from operating properly. This parameter is cumulative, new errors increase the value of the parameter.
The CollectionErrorCount value will be reset after a given time if no new errors are found. The default timeout is 135 minutes but can be configured with the following variable: /SENTRY/STUDIO/collectionErrorCountAutoAcknowledgeTime.
Value set by discoveryColl.
Errors
Alarm ≥ 1
Statistics
DebugStatus
Indicates whether the debug mode is enabled or not. Value set by studioColl.
{0 = Off ; 1 = On}
None
Availability
DiscoveryStatus
Indicates if the global discovery is currently running. Value set by discoveryColl.
{0 = Not Running ; 1 = Running}
None
Statistics
DiscoveryTime
Time taken to execute the global discovery. Value set by discoveryColl.
Seconds
None
Statistics
HostCount
Total number of Hosts managed by Monitoring Studio.
Note: Identical hosts are counted as if they were unique.
Value set by studioColl.
Hosts
None
Statistics
MonitorCount*
Total number of Monitors managed by Monitoring Studio.
Value set by studioColl.
Monitors
None
Statistics
* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in BMC TrueSight Operations Management.
Infobox
Name
Description
Product
Name of the product.
Version
Current version of the product.
Release Date