Back to the list of connectors

HP iLO Gen 10 (REST)

Connector file name: MS_HW_HPEGen10IloREST.hdf

Description

This connector discovers the status of an HPE Proliant Gen 10 system using iLO 5, as well as the various environment sensors (temperatures, fans, power supplies, etc.). Requires iLO 5.

Target

Typical platform: HP iLO Gen 10 REST

Operating system: Out-of-Band

Prerequisites

Requires KM Version: 10.3.00 or greater

Leverages:

Technology and protocols: HTTP/REST

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The HP iLO Gen 10 (REST) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The KM is in version 10.3.00 or greater
  • The HTTP Request below to the managed host succeeds:
    • GET /redfish/v1/
    • Request Header:
      EmbeddedFile(1)
    • The response body contains: iLO 5 (regex)

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Serial Number
  • Type
  • Vendor
  • Power Consumption
  • Status
Disk Controller (MS_HW_DISKCONTROLLER)
  • Firmware Version
  • Model
  • Serial Number
  • Controller Status
Battery (MS_HW_BATTERY)
  • Additional Information 1
  • Additional Information 2
  • Model
  • Charge
  • Status
Processor (MS_HW_CPU)
  • Maximum Speed
  • Model
  • Vendor
  • Status
Fan (MS_HW_FAN)
  • Additional Information 1
  • Status
Logical Disk, RAID (MS_HW_LOGICALDISK)
  • RAID Level
  • Size
  • Status
Memory Module (MS_HW_MEMORY)
  • Model
  • Serial Number
  • Size
  • Vendor
  • Status
Network Card, FC Port (MS_HW_NETWORK)
  • Model
  • Physical Address
  • Physical Address Type
  • Serial Number
  • Vendor
  • Link Speed
  • Link Status
  • Status
Physical Disk (MS_HW_PHYSICALDISK)
  • Additional Information 1
  • Firmware Version
  • Model
  • Serial Number
  • Size
  • Endurance Remaining
  • Status
Power Supply (MS_HW_POWERSUPPLY)
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Power (Nominal)
  • Power Supply Type
  • Status
Temperature Sensor (MS_HW_TEMPERATURE)
  • Additional Information 1
  • Alarm Threshold
  • Warning Threshold
  • Status
  • Temperature
Keywords:
hardware hdf patrol connectors