Type
  • Best practice
Description
  • This article explains what SSH credentials needs to be provided to access an EMC VNX disk array via a naviseccli command line.
Additional Keywords
  • naviseccli, EMC SMI-S, Celerra, VNX Disk Arrays, CLARiiON, SAN Monitoring, NAS Monitoring

Related Topics

Knowledge Base

EMC VNX Monitoring with Hardware Sentry Fails Because of Special Characters in the Password

KB1226 - Jun 28, 2018

Problem

Hardware Sentry uses SSH credentials to establish a direct access with an EMC VNX disk array through naviseccli command line. Most environments, and particularly Linux, do not support special characters such as escape characters, quotes, slash, etc. Using these characters prevents the password to be properly parsed and ultimately Hardware Sentry from monitoring EMC VNX systems.

Solution

The credentials used to establish a connection with an EMC VNX disk array through a naviseccli command line must be free from any special character (ex: ‘ ” ` / etc.).

You can easily test the credentials by performing the following command line from the server where naviseccli is installed:

naviseccli -User %{USERNAME} -Password %{PASSWORD} -Address %{HOSTNAME} -Scope 0 getagent