HC-694-KM: Brocade SAN Switches WBEM Connector: Devices Not Attached to Enclosure

Nov 22, 2017
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.02, 1.9.00, 1.9.50, 1.9.60

This patch is replaced with !

 Download

Patch content

Connector for Brocade SAN Switch SMI Agent

Should you install this patch?

Install this patch if devices such as CP modules, network interface, etc., are not being attached correctly to their enclosures.

What does it fix?

All devices related to their respective enclosures are now properly attached and reported.

How to install the patch?

  1. Copy the following file to the %PATROL_HOME%\lib\MS_HW_hdf or $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_BrocadeSwitchWBEM.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect. Nothing needs to be installed on Console systems.