Patches

P1249: Connector File for Dell EqualLogic PS Series

Nov 24, 2011
Patch for Hardware Sentry KM for PATROL - Version(s) 1.6.00, 1.6.01, 1.7.00, 1.7.01

This patch is replaced with !

 Download

Patch content

Connector file for monitoring Dell EqualLogic PS Series Disk Arrays.

Should you install this patch?

Apply this patch if you are monitoring a Dell EqualLogic Disk Array.

What does it fix?

This patch fixes an issue occurring when monitoring a Dell EqualLogic Disk Array with Hardware Sentry KM for PATROL. No error was raised when the physical disk status was "Offline".

How to install the patch?

  1. Copy the following files to the $PATROL_HOME/lib/MS_HW_hdf directory on the managed server:
    • MS_HW_Equallogic.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect.
  3. Add a remote monitoring of the EqualLogic Group using the Dell EqualLogic connector and specifying an SNMP community string.
  4. Nothing needs to be installed on Console systems.