Patches

P1745: Fujitsu Servers Running ESX - Missing Environment Sensors

April 22, 2016
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.01, 1.8.02, 1.9.00, 1.9.50

This patch is replaced with !

 Download

Patch content

Connector for Fujitsu-Siemens Serverview - WBEM

Should you install this patch?

Install this patch if you are only seeing one fan, power supply, temperature, or voltage sensor when monitoring your Fujitsu servers running ESX.

What does it fix?

Environment sensors were missing when the main identifier (caption) was blank. To solve this issue, the patched connector will now use the deviceID field to identify sensors.

How to install the patch?

  1. Copy the following file to the %PATROL_HOME%\lib\MS_HW_hdf or $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_ServerviewWBEM.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect. Nothing needs to be installed on Console systems.